MX Foundation 4
|
The following table lists the MAX Technologies' modules and devices supporting ASCB interface and the associated MX Foundation constant values. These MX Foundation constants are used by mxfDeviceModuleAllGet() to identify the ASCB interface available on a device.
Module model name | Module MXF constant |
---|---|
IPM-ASCB | MXF_MODULE_ASCBMRT |
The following table lists, for each device that supports ASCB, the part number and description.
Device | Note |
---|---|
MAX-IP-200118 | IPM-ASCB mezzanine module supporting Honeywell ASCB protocol versions A, B, C1 and C2. Provides simultaneous support of 128 users, a BC, as well as 4 Bus Monitors (BM) |
For each module, the channels are arranged this way:
Bus Function | Channel position |
---|---|
Bus Monitor (P1,B1,P2,B2) | 0-3 |
Bus Controller | 4 |
User (0-127) | 5-132 |